Talk:Ion chromatography (IC): Difference between revisions

From Saltwiki
Jump to navigation Jump to search
(Replaced content with "I moved the text to the content page ~~~~ SLeithaeuser 10:32, 21 September 2012 (CEST)")
 
Line 1: Line 1:
Author: [[user:Hschwarz|Hans-Jürgen Schwarz]]
I moved the text to the content page [[User:Hschwarz|Hschwarz]] 18:27, 27 November 2012 (CET)
<br>
<br>
back to [[Analysis of Salts]]
<br>
<!--
== Abstract ==
-->
== A brief explanation ==
 
Cromatography is one of several methods that can be used for the separation of substances. The method is base on having two phases: a stationary and a mobile one. A piece of filter paper can serve as a stationary phase or a tube or column, as it is usually called, is packed with materials such as alumina, Al<sub>2</sub>O<sub>3</sub>, activated carbon, ion exchange resins, etc. The mixture to be separated is dissolved in an appropriate solvent, in the case of salts, distilled water is used, that also serves as the mobile phase and fed into the column. Because of the difference in affinity between the substances to be separated in both the mobile and the stationary phase, they are separated as more and more solvent is passed through the column. The origin for the name chromatography stems back to the first separation of pigments found in spinach, such as chlorolphyl, carotenes, etc. so the stationary phase would be colored differently according to the affinity of the pigment for it.
 
In the case of ion chromatography, ions are also distributed between the stationary and the mobile phase and their separation is dependent on the partition coefficient of each specific ion. The surprisingly high separation efficiency of this relatively simple method is based on the many repetitions, between 100–10000, of individual separation operations during the on going passage of the mobile phase through the stationary one. In order to achieve the separation of chemically similar substances by chromatography, the partition coefficients of the two materials on the stationary phase have to differ at least slightly.
 
In the broadest sense, ion chromatography includes ion-exchange chromatography, ion exclusion chromatography, ion interaction chromatography (previously ion pair chromatography) and ion suppression chromatography.
 
Usually, the ion exchange chromatography is used for the detection of salt-forming ions<ref>http://www.chemgapedia.de/vsengine/vlu/vsc/de/ch/8/bc/vlu/proteinanalytik/chromatographie.vlu/Page/vsc/de/ch/8/bc/proteinanalytik/methoden_protein/fplc.vscml.html</ref>.
In general, an exchanger’s affinity for an oppositely charged sample ion is greater, the higher the charge and '''the smaller the sample ion’s surrounding solvation molecules are'''. Furthermore, the affinity increases with the polarizability of the ions.
 
<!--
Abbildung: Messanordnung  für eine Flüssigchromatographie mit der Möglichkeit zwei verschiedene Trägerflüssigkeiten zu  mischen. Die Probenzugabe erfolgt über ein Injektionsventil, als Detektor wird hier ein Photometer verwendet ( www.uni-mainz.de).
-->
 
The retention times <ref>the time required by each of the individual ions, referred to as analyte. for passing through the column, from injection to detection</ref>. The retention times for alkali and alkaline earth metals rise sequentially from lithium to cesium and magnesium to barium, because the polarizability of ions increases similarly, while solvation, the ability of these cations to form a hydration shell around them, increases in the opposite direction. The same applies to halogen anions from flourine to iodine. For other ions, the situation is not so clear. However, the bi- or higher valent ions elute after the monovalent ions. Protons and hydroxyl ions have a large hydration shell and therefore only a low elution strength. Retention behavior and selectivity of the separation are mainly influenced by pH-value, buffer <ref>acid-base pair that does not change in pH, when an acid or base is added</ref>, eluent ion<ref>carrier liquid or mobile phase of a gas</ref>, organic solvent '''additive or addition? (Lösungsmittelzusatz)''', and particularly heavy metals due to complexing agents. 
 
The detector of choice for ion chromatography is the conductivity detector. Yet, in some cases other detectors provide good services.
 
<!--
Abbildung 108: Chromatogramm für Kationen
Abbildung 109: Chromatogramm für Anionen
-->
 
'''Advantage:'''
Ion chromatography can be used for the analysis of cations and anions. However, it is mostly used for detecting anions, because there are better methods for the detection of cations. Ion chromatography provides accurate quantitative analyses.
 
 
'''Disadvantage:'''
Only ion concentrations can be determined, and complete salt-phases are determined by deduction, which is only possible for simple systems.
 
==Weblinks==
 
<references/>
<references/>
<references/>
<references/>
<references/>
 
<!--
== Literatur ==
 
-->
 
[[Category:Chromatography]] [[Category:Schwarz,Hans-Jürgen]] [[Category:R-MSteiger]] [[Category:R-CBlaeuer]] [[Category:Review]]
[[User:SLeithaeuser|SLeithaeuser]] 10:32, 21 September 2012 (CEST)
[[User:SLeithaeuser|SLeithaeuser]] 10:32, 21 September 2012 (CEST)

Latest revision as of 17:27, 27 November 2012

I moved the text to the content page Hschwarz 18:27, 27 November 2012 (CET) SLeithaeuser 10:32, 21 September 2012 (CEST)